HeadFineCalibration
From Wiki for RobotCub and Friends
This procedure describes how to correct small errors in the calibration of the iCub head. It applies mainly to the head joints (joint0...joint5). Note: this procedure has to be done after the calibration of the arms.
- Step 1: put the iCub in a suitable posture and let's call this configuration theta_desired in accordance to the convention you decided to use. As an example, if you decide to use the convention described in ICubForwardKinematics, you might decide to use the posture in the pictures which corresponds to theta_desired = [0 0 0 0 0] [deg] (remember we are just considering the five dof of the head).
- Step 2: read the robot posture as reported by the iCubInterface (e.g. using the robotMotorGui). Let's call this configuration theta.
- Step 3: for each joint compute the difference between theta and theta_desired. Let's call this difference Delta = theta - theta_desired.
- Step 4: consider Delta for joint i, called Delta(i). Add Delta(i) to the suitable Zeros entry (see also iCubInterface config file) in the iCubInterface configuration file. As an example if you want to change the left arm calibration (when using the icubSafe.ini initialization file), edit the icub_head_torso_safe.ini file as follows:
BEFORE: Zeros xxx yyy .... zzz
AFTER: Zeros xxx+Delta(0) yyy+Delta(1) ... zzz+Delta(5)